E1 loopback plug11/6/2023 Reconnect the E1 line to the original port.In this case, complete the following steps: Configure the port with the same settings as the line.If the problem does not persist, then the fault lies with the port. Connect the E1 line to a different port.Remove the loopback plug, and reconnect your E1 line.Check the settings at the remote end and verify that they match your port settings.If the problem persists, contact your service provider.Check the cable integrity by looking for breaks or other physical abnormalities in the cable.Correct the cable connections if necessary. Ensure that you have connected the cable to the correct ports. Ensure that you have correctly connected the cable between the interface port and the E1 service provider equipment or E1 terminal equipment. Issue the show controller e1 EXEC command to determine if any alarms occur.If you do not find any alarms, then the local hardware is probably in good condition.